Mark, thank you very much for your immediate response.
The question was, if the driver supports the "<" header instead of the "%" one, in order to have more devices in each telegram (faster communication).
The support from Sweden answered that, unfortunately, it is not possible.
Search found 19 matches
- Thu Oct 10, 2013 11:48 pm
- Forum: Controller Communication
- Topic: About Panasonic MEWTOCOL driver
- Replies: 2
- Views: 8363
- Thu Oct 10, 2013 11:40 pm
- Forum: Application Development
- Topic: Change direction of a linear meter
- Replies: 2
- Views: 5560
Re: Change direction of a linear meter
Thank you very much!
- Thu Oct 10, 2013 5:16 am
- Forum: Controller Communication
- Topic: About Panasonic MEWTOCOL driver
- Replies: 2
- Views: 8363
About Panasonic MEWTOCOL driver
Hi!
Does anyone know if the Beijer MEWTOCOL driver for Panasonic PLCs supports the expanded header (<) functionality or only the standard one (%)?
Also, has anyone tested the Beijer iX panels with Panasonic FP2-ET2 LAN card?
Does anyone know if the Beijer MEWTOCOL driver for Panasonic PLCs supports the expanded header (<) functionality or only the standard one (%)?
Also, has anyone tested the Beijer iX panels with Panasonic FP2-ET2 LAN card?
- Thu Oct 10, 2013 5:00 am
- Forum: Application Development
- Topic: Change direction of a linear meter
- Replies: 2
- Views: 5560
Change direction of a linear meter
Hi.
Does anyone know if we can change the direction of a horizontal linear meter?
I mean, can we have the max value at the left end and the min one to the right?
Does anyone know if we can change the direction of a horizontal linear meter?
I mean, can we have the max value at the left end and the min one to the right?
- Thu Aug 29, 2013 6:59 am
- Forum: Application Development
- Topic: About Recipes size & functionality in TxA
- Replies: 6
- Views: 11227
Re: About Recipes size & functionality in TxA
Thanks for your reply. Now, the problem is that it does not refresh the controlled tag on system tag's value change. I use the following code. If I remove the if statement it works o.k. public partial class Tags { void SystemTagLatestLoadedRecipeName_ValueChange(System.Object sender, Neo.Application...
- Wed Jul 31, 2013 5:12 am
- Forum: Application Development
- Topic: About Recipes size & functionality in TxA
- Replies: 6
- Views: 11227
Re: About Recipes size & functionality in TxA
Thank you for your answer Mark. The problem is that the System Tag "Latest Loaded Recipe" does not keep its value after the system start up. So, the "Load Last Recipe" button opens the Load Recipe pop-up, does not load the recipe itself. I can keep the value in the PLC but a 100 character string mea...
- Fri Jul 26, 2013 1:08 am
- Forum: Application Development
- Topic: About Recipes size & functionality in TxA
- Replies: 6
- Views: 11227
About Recipes size & functionality in TxA
Hi all. I'd like to ask some questions about “Recipes” functionality in iX TxA panels. 1. Which is the maximum available memory in TxA series, to use for recipes storage? Is there a formula to calculate the total recipes size in an application? 2. Is there a way to inform, at every system start up, ...
- Tue Mar 26, 2013 12:32 am
- Forum: Controller Communication
- Topic: Communication between TxA and Siemens LOGO (and S7-1200)
- Replies: 6
- Views: 20119
Re: Communication between TxA and Siemens LOGO (and S7-1200)
Thank you Mark,
I'll forward your answer to our customer.
I'll forward your answer to our customer.
- Fri Mar 22, 2013 6:27 am
- Forum: Controller Communication
- Topic: Communication between TxA and Siemens LOGO (and S7-1200)
- Replies: 6
- Views: 20119
Communication between TxA and Siemens LOGO (and S7-1200)
Hello! I work for Beijer distributor in Greece. A customer tries to communicate the iX TxA with a Siemens LOGO controller, as well as with a S7-1200, via the S7IsoTcp driver. For the first case he set the “system” to “S7-200”, the “Link” to “PG” and the other settings according to Beijer help file. ...