Search found 73 matches

by JohnCZ
Tue Mar 29, 2016 6:30 am
Forum: Controller Communication
Topic: FX3U melsec
Replies: 2
Views: 16203

Re: FX3U melsec

OR CAB 103
by JohnCZ
Mon Feb 08, 2016 5:03 am
Forum: Application Development
Topic: Write batch results to external SQL database
Replies: 4
Views: 15230

Re: Write batch results to external SQL database

Hi,

I will send you to your pm how it's possible to connect to your Microsoft SQL from TxA panel.

BR
JohnCZ
by JohnCZ
Thu Feb 04, 2016 5:31 am
Forum: Application Development
Topic: Write batch results to external SQL database
Replies: 4
Views: 15230

Re: Write batch results to external SQL database

Hi,

what type of databse you have Microsoft,MySQL,Oracle ??

what type of iX you used ( HMI or runtime app ) ??

BR
JohnCz
by JohnCZ
Fri Dec 18, 2015 9:24 am
Forum: Application Development
Topic: Importing Tags From Siemens TIA Portal V13
Replies: 3
Views: 15150

Re: Importing Tags From Siemens TIA Portal V13

Hi ricardo

first look here

http://www.jmobile.net/webpage?ReadForm ... BEI-9FNHY3

then, after you have the text file, just change it to the iX format which is importable.

BR
JohnCZ
by JohnCZ
Wed Nov 11, 2015 3:35 am
Forum: Controller Communication
Topic: Sample program for Allen Bradley SLC05/3 over DF1 + T7A
Replies: 1
Views: 13235

Sample program for Allen Bradley SLC05/3 over DF1 + T7A

Dear all,

we have problem to run comunication with SLC05/3 to T7A over DF1.

We used CAB104 between the panel and the PLC.

Could someone send me program to SLC05/3 and TxA panel over DF1? Only one screen with two tags..

Thank you

BR
JohnCZ
by JohnCZ
Tue Mar 03, 2015 8:23 am
Forum: Scripting
Topic: Data base file to be copied from IXT12B to PC using FTP
Replies: 1
Views: 6426

Re: Data base file to be copied from IXT12B to PC using FTP

Hi, Why you want send the database.sdf through FTP?? If you want through FTP You need to script your own FTP client and it's not so easy. If the PC and T12B is on the same network just used FileCopy method and add using System.IO. using System.IO; Exampl for Button void Button_Click(System.Object se...
by JohnCZ
Tue Dec 16, 2014 5:47 am
Forum: Ethernet and Serial Communications
Topic: Changing Baud or Node Address from runtime
Replies: 3
Views: 14639

Re: Changing Baud or Node Address from runtime

Hi onedumbtrucker, well, problem is that you cannot simply change baud rate of nod address when ix application is on. We have done something similar and what we do is that we have two files Controller1.cfg. In this file is stored all data from controller driver. So what you need is that operator thr...
by JohnCZ
Mon Dec 15, 2014 2:39 am
Forum: Application Development
Topic: Modbus TCP Unable to Open Port Error
Replies: 2
Views: 6639

Re: Modbus TCP Unable to Open Port Error

Hi, It is possible that you have not opened all ports that are required to communicate through modbus. Example when you need to communicate Beijer HMI and PLC from Mitsubishi through MODBUS TCP, then you need opened the port in PLC. L_ModBus_TCP.JPG Test your HMI with PC simulator. If HMI response t...
by JohnCZ
Thu Dec 04, 2014 7:22 am
Forum: Hardware
Topic: iX T15BM connected to DOT MATRIX Printer Epson/USB or Serial
Replies: 1
Views: 10522

Re: iX T15BM connected to DOT MATRIX Printer Epson/USB or Se

Hi, Because Windows Embedded CE has only a PCL printer driver , the following registry key entry is hard-coded into the registry to load the PCL driver. This enables testing all USB printers that support PCL print format. Non-PCL printers still support ASCII-only printing with the default PCL driver...
by JohnCZ
Tue Dec 02, 2014 2:42 am
Forum: Application Development
Topic: Quality of Support
Replies: 3
Views: 7007

Re: Quality of Support

The fact that Beijer does not support these forums is absolutely OK, because it's forum. Forum serves the community of people who use the same things and can cooperate or say tips on how to improve the application. Thanks to this forum I was able to solve a lot of requests from management. They have...